PDC Special $200 off Starter Bundle - Use code PDC2025 during checkout Shop Now

Shopping Cart

0

Your shopping bag is empty

Go to the shop

PanoraDX - Rapid Vitamin D test

Optimize dental implant success rate by assessing Vitamin D levels. PanoraDX helps mitigating the risks and ensures strong, long-lasting implants.

Why PanoraDX Vitamin D Test?

Identify Vitamin D Deficiency Quickly

Identify Vitamin D Deficiency Quickly

Vitamin D deficiency is linked to up to 300% increase in early implant failure rates compared to patients with normal Vitamin D level.

Enhance Implant Success

Enhance Implant Success

Detecting deficiencies before implant surgery allows dentists to adjust treatment protocols or prescribe appropriate supplementation.

Optimize Osseointegration

Optimize Osseointegration

Accurate Vitamin D measurement ensures that implants integrate effectively with the bone, reducing the likelihood of complications, helps combat periodontitis.

Science Behind the Success
Accurate & Reliable

Accurate & Reliable

PanoraDX utilizes a cutting-edge, direct two-site "sandwich" immunoassay to provide precise, quantitative measurement of 25-hydroxy Vitamin D levels.

Rapid Chairside Results

Rapid Chairside Results

With results available within 20 minutes, you can make immediate, informed decisions during the patient’s appointment.

<strong> Certified Performance </strong>

Certified Performance

Our testing method is DEQAS certified and clinically validated, ensuring high sensitivity and specificity.

Understanding the Risk

Before dental implant surgery, knowing your patient’s Vitamin D status is essential. Low Vitamin D levels impair bone healing, leading to complications, inflammation, and implant rejection. Geriatric patients & those with osteoporosis, diabetes, and cardiovascular issues are at higher risk of implant failure due to low Vitamin D.

Without testing for Vitamin D levels, a deficiency can compromise the implant procedure, extend patient care, and result in higher costs.

Clinical Data & Market Impact in United States and Canada
  • According to the American Academy of Implant Dentistry, the North American market sees over 789,000 dental implant procedures each year (approx. 500,000 in US), reflecting the growing demand for advanced dental restoration solutions.
  • The North American dental implant market generated a revenue of USD 2.33 billion in 2024 and is anticipated to reach USD 3.50 billion by 2030, with a CAGR of 7.3% from 2025 to 2030.

The PanoraDX Difference: Maximize Success, Minimize Risks

Unlike most other Vitamin D rapid tests that use a competitive immunoassay principle, the PanoraDX Quantitative Vitamin D Test employs an unique two-site "Sandwich" immunoassay on a membrane , utilizing direct binding immunochromatography.

The test features an exclusive pair of anti-25-OH Vitamin D monoclonal antibodies—one conjugated with colloidal gold and the other immobilized on the solid phase — ensuring highly sensitive and specific detection of Vitamin D.

Certified by DEQAS Since 2018

A Representation of High Accuracy

DEQAS stands for "Vitamin D External Quality Assessment Scheme," which is a program that monitors the accuracy and consistency of laboratories measuring Vitamin D levels, specifically 25(OH) citamin D, by distributing standardized serum samples to participating labs or manufacturers and comparing their results to a reference standard, allowing them to assess the quality of their assays and identify potential issues with their methodology.

Since 2018, PanoraDX’s 25(OH) vitamin D rapid assay has been evaluated by DEQAS program.

Results of DEQAS

Correlation Between PanoraDX’s 25 (OH) and LC/MS/MS

The Pearson correlation coefficient of 0.98 indicates a very strong positive correlation between the LC/MS/MS and PanoraDX vitamin D test. This suggests that the PanoraDX assay closely follows the LC/MS/MS measurements across a wide range of 25-hydroxy vitamin D concentrations. The high correlation coefficient implies that the PanoraDX assay is consistent with the LC/MS/MS method, which is considered the gold standard. This strong correlation supports the reliability of the PanoraDX assay for clinical use.

Sensitivity: The sensitivity of PanoraDX Vitamin D Test is 3ng/ml (7.5 nmol/l).

Detection Range: The Detection Range of PanoraDX Vitamin D Test with QuickStatus® CUBE READER is from 3ng/ml (7.5 nmol/l) to 100ng/ml (250 nmol/I).
Key Benefits for Your Practice
<strong>Lower Implant Failure Risk</strong>

Lower Implant Failure Risk

Addressing Vitamin D deficiencies can lead to a significant reduction in implant failure rates. Enhanced osseointegration means more durable, long-lasting implants, leading to higher patient satisfaction.

<strong>New Revenue Stream</strong>

New Revenue Stream

Including Vitamin D screening as a standard part of the pre-surgical assessment can create a new revenue stream while enhancing patient satisfaction with the overall implant experience.

<strong> Efficient, Streamlined Workflow</strong>

Efficient, Streamlined Workflow

Quick and easy—no special training needed. This fast, painless finger-prick test delivers rapid, on-site results, eliminating the wait for lab reports and streamlining your pre-surgical evaluations seamlessly.

Creating better outcome by mitigating risks - Order PanoraDX now.

Free Shipping within Canada and USA included.